I service and repair Vaillant boiler models ranging from.
  • VCW models 1988 - 1996.
  • TURBOmax VUW Combi Boilers 1996 - 2000.
  • THERMOcompact VU System boilers
  • turboMAX Plus VUW Combi Boilers 2000 - 2005.
  • thermoCOMPACT VU System Boilers
Book Service

TURBOmax and THERMOcompact


In production 1996 - 2000

These boilers are some of the best that Vaillant made.

They came with built-in diagnostic indicator lights which illuminated in sequence, indicating the operational status of the boiler. 

This feature provides key information to aid commissioning and depending on flashing coloured lights, fault finding.


Call Tony on 07831 623711

Read more

Most common faults with TURBOmax and THERMOcompact boilers


These boilers have no major faults other than if they were installed on a dirty heating system, the Differential Pressure Switch and small Hydraulic tubes would get blocked with sludge. 

The Diverter valve would also suffer from sticking and small leaks, stopping the micro-switch from turning the boiler on whenever hot water was required. 

When these boiler get a service we need to check the condition of the auto air vent for signs of leakage and the burner insulation pads for any cracks.

Call Tony on 07831 623711

turboMAX plus and thermoCOMPACT Boilers


In production from 2000 - 2005

This is the text area for this paragraph. To change it, simply click and start typing. Once you've added your content, you can customise its design by using different colours, fonts, font sizes and bullets. Just highlight the words you want to design and choose from the various options in the text editing bar. 

Call Tony on 07831 623711

Read more

Vaillant annual boiler service. 

 

  • Conduct a system Gas Soundness Test.
  • Check the Air/Gas Flue System.
  • Measure the Gas Rate during operation.
  • Check Combustion with a Flue Gas Analyser.
  • Visually inspect boiler for corrosion or damage.
  • Check/ re-pressurise the Expansion Vessel.
  • Check and clean the ignition electrodes.
  • Check for dirt/ dust and clean.
  • Clean Fan, Heat exchanger and Burner
  • Re-pressurise the boiler/ system (1-2 bar).
  • Check Boiler for any leaks.
  • Record service visit in Manufacturers booklet.
  • Carry out electrical safety checks on boiler.
  • Fill out service sheet, send via email.



Call Tony on 07831 623711

Booked an Annual Service

Cost of Boiler Services

Diagnostic fee

£50.00

Up to an Hours Work

Some faults with boilers are not obvious and various tests have to be performed on the gas supply or electrical components before you can pinpoint the defect and give a quote.
If you choose not to proceed with the Quote, you will still be required to pay the diagnostic fee.
More Info

Annual Boiler Service

£70.00

Per Service

Conducted every year
Check your household Gas supply for any leaks
With full Service Work Sheet

Flue Gas Analyser Tests carried out and sent via email