I carry out servicing and breakdowns of Vaillant , Glow Worm, Worcester Bosch , Potterton, Baxi, Main and Boilers.
If a service is booked please remember to turn off the boiler at least 30 mins before my visit.
NB. Condensing boiler have seals on the heat exchangers and burners and can only be changed if a FULL Heat exchanger Strip down Service has been paid for. Please see our Prices .
Call Tony on 07831 623711
1, Regular Topping Up of System water.
(It is never a good idea to keep filling your system as this always leads to corrosion within the boiler).
You may see the pressure gauge on zero when cold or over 3 bars when hot.
Potential causes include, leaky parts in boiler, radiator leaks, valves or unions, pipe work, heat exchanger or expansion vessel problems.
2, Boiler Leaking and Dripping.
Potential causes include, leaks on pump, auto air vents, diverter valves ( leaking when moving from heating to hot water modes ), Condensate drainage or if dripping outside then the pressure relief valve is letting by.
3, No Heating or No Hot Water.
Some of the probable causes include, pump failure, diverter valve ( mechanical or electrical defect ), hot water flow switch, heating or hot water sensors playing up, printed circuit board electrical defect.
4, Boiler Display Showing Fault Code.
Many modern boilers have some type of fault display.
The older type may have just neon lights and any combination of flashing will indicate the type of fault.
Usually in the back of the installation and service booklet you will find the information to decode what's on display. It's a good idea to write down the fault code to help with fault finding, some boilers have a fault code memory which can be called up by the engineer.
5, Boiler Making Unusual Noises.
The usual suspects are the pump has stopped, air is trapped inside the boiler, sludge/scale build up within the plate or main heat exchanger's, excessive mains water pressure or defective water governor/flow switch. Condensing boilers may need the gas valve resetting or the condensate drain may have become blocked.
1, Radiator/s Not Getting Hot.
The heating system could be air locked, stopping circulation. Either the thermostatic radiator valve is defective or a manual radiator valve not turned on. The heating zone or diverter valves actuator heads are faulty.
The central heating pump has stopped working. The room thermostat has become defective or if a wireless type check the batteries.
2, No Hot Water.
On hot water storage cylinders the cylinder stat could be faulty or either the hot water zone valve or diverter valve could be playing up, usually the actuator heads need replacing. The central heating pump has stopped working or the programmer is not calling for hot water.
The immersion heater elements could have blown the electrics.
3, The Boiler is Not Working.
The first thing to check is whether the display or power light is on, if not check the fuse in the adjacent power spur box or fuse board. If the boiler has 240v power check it ignites, the gas supply could have been shut off at the gas meter, or the boiler's gas valve could have become faulty.
4, System Controls or Wiring Faulty.
The cylinder thermostat on the side of the hot water cylinder may have a loose or pulled wiring connection, or internal switch/relay burnt out and stuck in open position. The Room thermostat may have battery issues, switching contacts burnt out or set too low. The central heating programmer feeds 240v live to both thermostats above and may have an internal fault. Zone valves or a Diverter valve then switches on to send power to pump and boiler.
If pump or boiler doesn't switch on you are looking at possible defective zone or diverter.
5, Poor Circulation or Cold Spots on Radiators.
Heating systems now should have a magnetic filter near the boiler which becomes blocked with sludge and magnetite deposits, they should be cleaned when the boiler is serviced. Chemical cleaner can be introduced in to heating system and allowed to work on sludge build up then a gravity flush of the system until the drained water runs clear is a good method of keeping the system in good health. Power flushing is for heavily blocked systems.
Call Tony on 07831 623711